TESTBENCHES FOR ALTERNATORS 10 TO 2000 KVA

TEST BENCH FOR ALTERNATORS WITH PURELY REACTIVE LOAD

Test bench for synchronous and asynchronous alternators

Power range 10 – 2000 KVA

Speed range 1000 – 4000 RPM

Voltages: 400 50 Hz and 480 Vac 60 Hz

Load bank: purely inductive, 1 KVA step

Test control via PLC and PC (automatic or manual)

Short circuit test

Analog and digital instruments

PC based GenTEST AL software for test bench control, data acquisition, storing, retriva, reports

Download brochure pdf (630 KB)

NEW FULL LOAD REGENERATIVE TEST BENCH FOR ALTERNATORS

Power range 10 – 2000 f.s. KVA

Speed range 1000 – 4000 RPM

Continuously variable voltage: 200 to 480 Vac

Frequencies: 40 to 200 Hz

Variable Power factor: -1 to 0 and 0 to 1

Power range: 10:1

Driving motor + inverter

Electronic load based on electronic frequency converters

Test control via PLC and PC (automatic or manual)

Analog and digital instruments

PC based GenTEST AL software for test bench control, data acquisition, storing, retriva, reports

 

ITA

EN

 

INTESYS Srl - Testing Systems

Viale Pasubio, 25/4 - 36030 Caldogno (Vicenza) – tel +39 0444 905440 fax +39 0444 1830 932 - skype: intesyssrl - info@intesys-srl.it