LOAD BANKS AND DISSIPATIVE MODULES FOR PHOTOVOLTAIC AND

FUEL-CELL SYSTEMS WHEN NO POSSIBILITY TO EXPORT ENERGY TO THE GRID

 

When

·         It is not possible or not allowed to export the electrical energy to the grid AND

·         Generated energy is greater than consumed energy

·         You must use all energy created in excess.

 

PhotoLOAD uses all the excess energy by adapting to the energy produced

by the photovoltaic system

GRID

User Power

Consumption

(PA)

RM 2OO-5-T

Dissipative

Module

5KW steps

ARM-PV

Load

Regulator

200 KW

Photovoltaic/Fuel-cell

System

% of avaiable power (AP)

4..20 mA or 0..10 V

Signal from inverter

 

Regeneration

Not Allowed

MODEL

DESCRIPTION

POWER

VOLTAGE AND FAN

Vac/Vdc

Weight

Photoload with vertical ventilation for small PV-FC systems up to 50 KW, continuous use, AluZinc housing, IP20, with automatic adjustment for consumption of the exceeding power generated by PV-FC system.

3-Phase and 1-Phase

 

7, 10, 16, 35 and 50 KW models

Photoload with horizontal ventilation for PV-FC systems, up to 500 KW, continuous use, AluZinc housing, IP23 with automatic adjustment for consumption of the exceeding power generated by PV-FC system, 3-Phase

Photoload with horizontal ventilation for PV-FC systems, up to 2000 KW, continuous use, AluZinc housing, suitable for 10” standard ISO container, IP23 with automatic adjustment for consumption of the exceeding power generated by PV-FC system, 3-Phase

1200, 1500 and 2000 KW 3-phase models

1-Phase models 3 and 5 KW

3-Phase models 7, 10, 16, 35 and 50 KW

 

330 W 1-Phase steps

1 KW 3-Phase steps

3-Phase

250, 300, 400 and 500 KW

 

5 KW 3-Phase steps

3-Phase

1200, 1500 and 2000 KW

 

50 KW 3-Phase steps

400V 3phase 50Hz

230V 1phase 50Hz

480V 3phase

60 Hz

240V 1phase

60 Hz

400V 3-Phase 50Hz

480V 3-Phase 60 Hz

3-Phase

400 V 50 Hz

690 V 50 Hz

400V 3-Phase 50Hz

230V 1-Phase 50Hz

480V 3-Phase 60 Hz

240V 1-Phase 60 Hz

400V-480V

5,5KW

400 – 480 V

4 x 5,5 KW

650 W

900 D

950 H

2300 W

1300 D

1300 H

 

2000 W

2700 D

2100 H

 

150

500

500

Photoload with vertical ventilation for PV-FC systems up to 200 KW, continuous use, AluZinc housing, IP20, with automatic adjustment for consumption of the exceeding power generated by PV-FC system, 3-Phase

 

100, 150 and 200 KW 3-Phase models

Photoload with horizontal ventilation for PV-FC systems, up to 1000 KW, continuous use, AluZinc housing, IP23 with automatic adjustment for consumption of the exceeding power generated by PV-FC system, 3-Phase

 

700, 800 and 1000 KW 3-phase models

3-Phase

100, 150 and 200 KW

 

1 KW 3-Phase steps

3-Phase

700, 800 and 900 KW

 

10 KW 3-Phase steps

400V 3-Phase 50Hz

480V 3-Phase 60 Hz

400V 3-Phase 50Hz

480V 3-Phase 60 Hz

230 V, 50Hz

240V, 60Hz

1 KW

400V-480V

2 x 5.5KW

800 W

1100 D

1900 H

2300 W

1400 D

2100 H

350

850

ITA

EN

 

INTESYS Srl - Testing Systems

Viale Pasubio, 25/4 - 36030 Caldogno (Vicenza) – tel +39 0444 905440 fax +39 0444 1830 932 - skype: intesyssrl - info@intesys-srl.it